KNX Power Supply

Υλικά τροφοδοσίας ΚΝΧ καθώς και διασύνδεσης, διακλάδωσης γραμμών KNX.

Pos.1 KNX Bus Power Supply STV Series.

The MDT KNX / EIB Power Supply with integrated choke produces the stabilized KNX system voltage (30VDC) to supply the connected KNX / EIB components. The operating status is indicated via 3 LED.

STV-0160.02 e-shop KNX horos Bus Power Supply, 2SU MDRC, 160mA.
STV-0320.02 e-shop KNX horos Bus Power Supply, 2SU MDRC, 320mA.
STV-0640.02 e-shop KNX horos Bus Power Supply, 4SU MDRC, 640mA Best Seller!

  • KNX power supply with integrated choke.
  • Mains voltage 230VAC.
  • Short-circuit-proof. Overload safe.
  • Temperature control with shutdown on over temperature.
  • LED indicator for bus reset, normal operation and bus overload.
  • Choke free output (STV-640.02 only).
  • Modular installation device for DIN 35 mm rails.
  • Integrated bus coupling unit.
  • Production in Germany, certified according to ISO 9001

Pos.2 KNX Bus Power Supply With Diagnostic Function, STC Series.

The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC.

STC-0640.01 e-shop KNX horos Bus Power Supply diagnostic function, 4SU MDRC, 640mA.
STC-0960.01 e-shop KNX horos Bus Power Supply diagnostic function, 6SU MDRC, 960mA.
Εξαιρετική Επιλογή + Best Seller!
STC-1280.01 e-shop KNX horos Bus Power Supply diagnostic function, 6SU MDRC, 1280mA.

The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltage failure / return. All events are stored with time stamp in the internal ring buffer. The current operating status is indicated via 8 colored LED on top of the device:

  • KNX power supply with integrated choke
  • Mains voltage 230VAC.
  • Short-circuit-proof. Overload safe.
  • With additionally choke free output.
  • Integrated bus coupling unit with diagnostic function:
  • Bus voltage, bus current, bus overload.
  • Bus voltage failure / return.
  • All events are stored with time stamp in a ring buffer.
  • Read out of the ring buffer by 14 Byte telegram.
  • Safety functions to detect a failed device in the KNX line.
  • Production in Germany, certified according to ISO 9001

Pos.3 KNX Bus Power Supply, Redundant, STR Series.

The MDT KNX Power Supply with integrated choke supplies the KNX Bus with a constant, stabilized 30VDC voltage.

STR-0640.01 e-shop KNX horos Redundant Bus Power Supply with diagnosis function, 6SU MDRC, 640mA

The redundant Bus Power Supply has two integrated power supplies to increase operation reliability. If one mains voltage or one of the internal power supplies fails, the KNX bus voltage maintains its stability by the second power supply. The integrated bus coupling unit with diagnostic function monitors the bus voltage, bus current, bus overload and bus voltage failure / return. All events are stored with time stamp in the internal ring buffer. The ring buffer can be read out by a 14 Byte telegram.

  • KNX power supply with integrated choke.
  • Two integrated power supplies for redundancy.
  • Mains voltage 230VAC (separate FI circuits possible).
  • If one mains voltage or one of the internal power supplies fails, the KNX bus voltage maintains its stability by the second power supply.
  • Failure message by a telegram. Short-circuit-proof, Overload safe.
  • With additionally choke free output.
  • Integrated bus coupling unit with diagnostic function:
  • Bus voltage, bus current, bus overload.
  • Bus voltage failure / return.
  • All events are stored with time stamp in a ring buffer. Read out of the ring buffer by 14 Byte telegram.
  • Safety functions to detect a failed device in the KNX line.
  • Production in Germany, certified according to ISO 9001

Pos.4 KNX IP Interface, IP Router, USB Interface

The IP Interface enables the communication between the PC and the KNX / EIB system via LAN.

SCN-IP000.03 e-shop KNX horos IP Interface, with IP Secure and Data Secure 2SU MDRC.
Εξαιρετική Επιλογή!
SCN-IP100.03 e-shop KNX horos IP Router, with IP Secure and Data Secure 2SU MDRC.

The KNX IP Interface allows to programm the KNX bus via TCP/IP, 4 simultaneous connections possible.
KNX IP Router: Same functions plus the device routes telegrams as a Line Coupler using the the LAN.

  • Programming the KNX bus via TCP/IP. 4 simultaneous connections possible.
  • Power supply by KNX bus, no external bus power supply required.
  • Encrypted transmission for sending emails.
  • Time server functions to send time and date on the KNX bus.
  • Firmware can be updated. Supports extended group addresses.
  • KNX IP Secure and KNX Data Secure (from ETS 5.7).
  • Secure access to the KNX bus through IP Secure with security key.
  • Production in Germany, certified according to ISO 9001

SCN-USBR.02 e-shop KNX horos USB Interface, 2SU MDRC

  • Communication between PC and the KNX bus via USB
  • Fully compatible with ETS 4/5/6. Supports PC sleep mode.
  • Firmware can be updated. Integrated bus coupling unit
  • Production in Germany, certified according to ISO 9001

Pos.5 KNX Line Coupler

This Interface connects two KNX lines to each other. Electrical isolation between the lines and reduction of the bus-load by using the filter function.

SCN-LK001.03 e-shop KNX horos Line Coupler with Data Secure, 2SU MDRC.

  • Line Coupler to connect two KNX lines to each other.
  • Electrical isolation between the lines. Separate bus power supply for each line required.
  • Filter functions to reduce bus load. Supports extended group addresses.
  • Supports KNX Data Secure (from ETS 5.7.2). Integrated bus coupling unit.
  • Production in Germany.Certified according to ISO 9001

Pos.6 KNX Safety Module.

The MDT security module prevents all connection-oriented accesses of the ETS such as the programming and also the unloading of the bus devices in the KNX line.

SCN-SAFE.01 e-shop KNX horos Safety Module, 2SU, MDRC

Significantly increases the safety of the protected line. The safety function is started automatically after bus voltage recovery / programming of the safety module. The deactivation of the safety function is possible depending on the set safety level via the control buttons on the device and / or with the safety password via telegramm. The integrated device monitoring system controls up to 100 KNX devices cyclically. As soon as a device is missing or no longer responds due to a defect, an alarm message is sent.

  • Blocks the connection and prevents the programming and discharging of KNX devices within the line.
  • Safety function is started automatically after bus voltage recovery and / or programming of the Safety Module.
  • Safety function can be temporarily disabled by pressing the button on the device or 14 Byte telegram.
  • Safety function for detecting a failed device in the line.
  • Active or passive monitoring of up to 100 KNX devices.
  • Alarm is stored as plain text message in the internal ring memory.
  • Integrated bus coupling unit.

Pos.7 Power supply 24VDC.

Power supply 24VDC for universal applications.

STV-0024.01 e-shop KNX horos Power supply 24V DC

  • SELV power supply 24VDC for universal applications.
  • Suitable for VisuControl touch panel.
  • Supply voltage 230V AC.
  • Short circuit proof.