 RFTF-Modbus
 RFTF-Modbus-PT5L
|
 RFTF-Modbus with display
 RFTF-Modbus-PTD55L
|
RFTF-Modbus
Quality product for HVAC sector, accuracy ±2%
The calibratable room sensor HYGRASGARD RFTF - Modbus with Modbus connection, with or without optional display in an elegant enclosure (Baldur 2).
It is used to measure the relative humidity and the temperature of the room air. These measurands are used to calculate various parameters internally. The Modbus can be used to retrieve the following parameters: relative humidity [% r.H.], absolute humidity [g/m3], mixture ratio [g/kg], dew-point temperature [°C], enthalpy [kJ/kg] (ignoring atmospheric air pressure) and room temperature [°C].
Manual σε pdf
|
 RTM1-Modbus with display
 RTM1-Modbus-P with potentiometer
|
 RTM1-Modbus-P with display & potentiometer
|
RTM1-Modbus
Calibratable room temperature measuring transducer THERMASGARD RTM1 Modbus With Modbus connection, with???without optional display for displaying the actual temperature, in an elegant enclosure made of plastic, with snap-on lid, base with 4-hole attachment, for installation on vertically or horizontally installed in-wall flush boxes, with predetermined breaking point for on-wall cable entry.
The calibratable room operating sensor measures the temperature of non-aggressive gases, particularly air. In this case, a setpoint potentiometer is available as an operating element. Optional devices with LCD displays for displaying readings are available for temperature/humidity/dew point or setpoint readings. The displays (LCD) and the retrieval of measurement and control values are triggered via the Modbus interface.
Sensor: Digital
Output: Modbus
Manual σε pdf
|
 ATM 2-Modbus
|
 ATM 2-Modbus display
|
ATM 2-Modbus
Calibratable outside temperature measuring transducer with internal or external sensor THERMASGARD ATM 2 - Modbus with Modbus connection, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with/without optional display indicating the actual temperature.
It is used to detect outside temperatures, temperatures in wet rooms e.g. for installation on outside walls, in cold storage buildings and greenhouses, in the industrial sector and in agriculture. Installation in outdoor areas preferably at the north side of a building or in a protected place. In case of direct sun irradiation, the sunshade and ball game protection WS 01 or WS 04 (accessories) or the device variant with the installed sunshade SS 02 (available on request) must be used. The outdoor sensors are factory-calibrated. Adjustment/fine adjustment by the user is possible (zero point offset is adjustable).
Manual σε pdf
|
 HFTM-Modbus
|
 HFTM-Modbus with display
|
HFTM-Modbus
Calibratable temperature measuring transducer with sleeve sensor THERMASGARD HFTM - Modbus with Modbus connection, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with/without optional display indicating the actual temperature.
The temperature transmitter with remote sensor is used to detect temperatures in liquid and gaseous media e.g. if installed in an immersion sleeve or as a duct sensor. The sensors are factory-calibrated. Adjustment/fine adjustment by the user is possible (zero point offset is adjustable).
Manual σε pdf
|
 AFTF-SD-Modbus |
 AFTF-SD-Modbus display
|
AFTF-SD-Modbus
Quality product for HVAC sector, accuracy ±2%
Calibratable outdoor humidity and temperature sensor HYGRASGARD AFTF-SD-Modbus with Modbus connection, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with/without optional display.
The universal on-wall sensor is used to detect various parameters in humidity measurement. The relative humidity and temperature of the ambient air are measured. These measurands are used to calculate various parameters internally. The Modbus can be used to retrieve the following parameters: relative humidity [% r.H.], absolute humidity [g/m3], mixture ratio [g/kg],dewpoint temperature [°C], enthalpy [kJ/kg] (ignoring atmospheric air pressure) and ambient temperature [°C].
It is used in non-aggressive, dust-free environments, in the refrigeration, air conditioning and clean room technology, hotels, engineering rooms, meeting and conference facilities. The measuring transducers are designed for exact detection of temperature and humidity. A digital, long-term stable sensor is used as a measuring element for humidity and temperature measurement. Fine adjustment by the user is possible.
Manual σε pdf
|
 KFTF-Modbus
|
 KFTF-Modbus with display
|
KFTF-Modbus
Calibratable duct humidity and temperature sensors HYGRASGARD KFTF-Modbus (±3%) or KFTF-20-Modbus (±2%) with plastic sinter filter (optional metal sinter filter), with Modbus connection, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with/without optional display.
The universal duct sensor is used to detect various parameters in humidity measurement. The relative humidity and temperature of the ambient air are measured. These measurands are used to calculate various parameters internally. The Modbus can be used to retrieve the following parameters: relative humidity [% r.H.], absolute humidity [g/m3], mixture ratio [g/kg],dewpoint temperature [°C], enthalpy [kJ/kg] (ignoring atmospheric air pressure) and ambient temperature [°C].
It is used in non-aggressive, dust-free environments, in the refrigeration, air conditioning and clean room technology, hotels, engineering rooms, meeting and conference facilities. The measuring transducers are designed for exact detection of temperature and humidity. A digital, long-term stable sensor is used as a measuring element for humidity and temperature measurement. Fine adjustment by the user is possible. The sensor is suitable for ceiling and duct installation or for integration in equipment.
Manual σε pdf
|
 VFTF-Modbus
|
 VFTF-Modbus with display
|
VFTF-Modbus
Calibratable showcase humidity and temperature sensor HYGRASGARD VFTF-Modbus with Modbus connection, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with/without optional display.
The universal showcase sensor is used to detect various parameters in humidity measurement. The relative humidity and temperature of the ambient air are measured. These measurands are used to calculate various parameters internally. The Modbus can be used to retrieve the following parameters: relative humidity [% r.H.], absolute humidity [g/m3], mixture ratio [g/kg],dewpoint temperature [°C], enthalpy [kJ/kg] (ignoring atmospheric air pressure) and ambient temperature [°C].
The measuring transducers are designed for exact detection of temperature and humidity. A digital, long-term stable sensor is used as a measuring element for humidity and temperature measurement. Fine adjustment by the user is possible.
The showcase sensor is used in non-aggressive, dust-free environments and is specifically designed for installation in ceilings, walls, inside showcases or display cabinets in museums, galleries, cinemas or lecture halls or laboratories. The measuring element is contained inside a stainless steel probe and its low height (approx. 2.5 mm) makes it barely noticeable.
|
 PREMASGARD 121x-Modbus
|
 PREMASGARD 121x with display
|
PREMASGARD 121x-Modbus
The calibratable, compact pressure sensors PREMASGARD 121x-Modbus (series) with Modbus connection can be equipped with an optional display and are used for measuring above-atmospheric, below-atmospheric or differential pressures in the air. The piezoresistive measuring element is temperature-compensated and guarantees a high degree of reliability and accuracy. The pressure transmitters feature a configurable offset and a button for manual zero adjustment.
Applications of these pressure sensors are in clean room, medical and filter technology, in ventilation and air conditioning ducts, in spray booths, in large-scale catering facilities, for monitoring filters, for level measurement or for triggering frequency converters. Media measured with these pressure transducers are air (non-precipitating), or other gaseous non-aggressive, non-combustible media. The differential pressure sensor is supplied including the ASD-06 connection set (2m connection hose, two pressure connection nipples, screws).
Manual σε pdf
|
 RYMASKON 412/422
 RYMASKON 400 Display
|
 RYMASKON 411/421
|
RYMASKON 400
RYMASKON stands for a series of multifunctional room control units. The individually configurable RYMASKON 400 - Modbus enables automated monitoring and control of the indoor climate and illumination in a Modbus network. It has two digital inputs and two digital/analogue outputs. Room climate control and regulation can be accessed from a central point on a higher-level Modbus master and on-site operation can be selectively or completely disabled. Thanks to its internal outputs, the inputs and settings on the device do not necessarily have to be processed by the master. This means that it is also possible to have decentralised individual room control at any time. An internal sensor detects the room temperature.
Six freely assignable function buttons on the front panel of the unit can be used for on-site operation and configuration. An integrated rotary encoder with a central input button enables manual adjustment of settings and parameter assignment on location. Desired functions (such as "Light ON") and display values can be activated by triggering an approximation sensor when entering the room.
The dimmable multifunctional display is designed specifically for room operation and uses intuitive symbols for a clear view of all available spatial data. Besides the time, weekday and climate parameters (temperature, humidity, dew point, CO2 content), it can also display additional features, such as heating/cooling and fan modes, window open, lighting, alarm, key lock or room occupancy.
RS485 Modbus RTU Slave
Temperature: 0...+70 °C
Manual σε pdf
|
 RYMASKON 211/221
|
 RYMASKON 212/222
|
RYMASKON 200
RYMASKON stands for a series of multifunctional room control units. The individually configurable RYMASKON 200 - Modbus enables automated monitoring and control of the indoor climate and illumination in a Modbus network. It provides three digital inputs and a universal input, which allows connection of up to four external push buttons or switches. It can be configured remotely from a higher-level Modbus master and integrated into a cross-building room climate monitoring and data acquisition system. Internal sensors record room temperature, relative humidity and dew point.
Up to eight capacitive function buttons on the front panel of the compact unit can be used for on-site operation and configuration. A buzzer sounds to acknowledge button use and can also be used as an acoustic fault or alarm warning.
The dimmable multifunctional display is designed specifically for room operation and uses intuitive symbols for a clear view of all available spatial data. Besides the time, date and climate parameters (temperature, humidity, dew point, CO2 content), it can also display additional features, such as fan mode or room occupancy. The back light colour can be adapted to the room design.
RS485 Modbus RTU Slave
Temperature: -40...+125 °C
Humidity: 0...100% r.H.
Manual σε pdf
|